Lamson Pipe Company manufactures the most complete line of Schedule 40 and 80 Conduit, P&C Duct, and Telephone Duct in the electrical industry.

Schedule 40 and 80 Conduit

490* Series - Schedule 40 PVC Rigid Nonmetallic Conduit (Heavy Wall EPC)
  • Listed for underground applications encased in concrete or direct burial.
  • Also for use in exposed or concealed applications aboveground.
  • Rated for use with 90°C conductors
494* Series - Schedule 80 PVC Rigid Nonmetallic Conduit (Extra Heavy Wall EPC-80)
  • Listed for use in aboveground and belowground applications including areas subject to physical damage.
  • Rated for use with 90°C conductors
  • Superior weathering characteristics
  • Identified for use in areas subject to physical damage in accordance to 352.12(C)
490*CC Series - Schedule 40 PVC Rigid Nonmetallic Conduit (Heavy Wall EPC)
  • Meets CSA Standard C22.2 No. 211.1
  • Certified for underground applications encased in concrete or direct burial.
  • Also for use in exposed or concealed applications aboveground.
  • Rated for use with 75°C conductors
596* Series – Heavy Wall Schedule 40 Utility Conduit
  • Rated for 90°C conductors or cable
  • For direct earth burial and concrete encasement, specifically designed for power utility specifications
   

P&C Duct – Power and Communications Duct

487* Series - Type EB-20 (EB-20/ASTM F-512)
687* Series - Type EB 35 (EB-35/ASTM F-512)
  • Rated for 90°C Cable.
  • Meets NEMA Standard TC-6 & 8
  • Developed especially for power and communications applications
  • For use in concrete encased installations.
48811-48817 Series - Type DB-60 (DB-60/ASTM F-512)
48808-48810; 688* Series - Type DB-120 Heavy Wall (DB-120/ASTM F-512)
  • Rated for 90°C Cable.
  • Meets NEMA Standard TC-6 & 8
  • Developed especially for power and communications applications
  • For use in direct burial or concrete encased installations.
689* Series – Special California Type DB-100 (ASTM F-512)
  • Meets NEMA Standard TC-6 & 8
  • State of California specifications
  • For use in direct burial or concrete encased installations.
  • Rated for 90°C Cable.
   

Telephone Duct

683* Series – Type B
684* Series – Type B Heavy Wall
  • For use in concrete encased installation
  • Meets the requirements of NEMA TC-10
  • Conforms to Bellcore CAO8546.
685* Series – Type C;
  • For use in direct bury or concrete encased installation
  • Meets the requirements of NEMA TC-10
  • Conforms to Bellcore CAO8546.
685*L Series – Pre-lubricated Type C (Tel-Gard)
  • For use in direct bury
  • Meets the requirements of NEMA TC-10
  • Exceeds Bellcore minimum coefficient of friction
686* Series – Type D
  • For use in exposed applications